Scope of application

IDM1L and IDM8L plastic case earth leakage circuit breakers are a new type of circuit breaker developed by the company using leading CAD/CAM/CAE design and manufacturing technology. With rated insulation voltage of 800V, they are suitable for infrequent switching and infrequent starting of motors in circuits with AC 50Hz, rated working voltage of AC400V and rated current to 800A. The circuit breaker has overload, short-circuit and ⽋-voltage protection functions, which can protect lines and power supply equipment from damage, as well as provide indirect contact protection for people and protection against fire hazards caused by long-lasting ground faults that cannot be detected by overcurrent protection. When other protection devices fail, the circuit breaker with a rated residual action current of 30mA can provide additional protection against direct contact.

The circuit breaker is characterized by small size, high interruption, short working arc, and vibration resistance.

The circuit breaker can be installed vertically (i.e. vertical installation) or horizontally (i.e. horizontal installation).

◆The circuit breaker can not be inverted into the line, that is, only 1, 3, 5 allowed to connect to the power line, 2, 4, 6 connected to the load line.

◆The circuit breaker products conform to the following standards.

IEC60947-1 and GB14048.1-2006 General Provisions

IEC60947-2 and GB14048.2-2008 circuit breakers and Appendix B circuit breakers with residual current protection

◆The circuit breaker is suitable for isolation and the symbol table is shown as“图层1.jpg”。


Applicable working environment and installation conditions

◆The temperature of the surrounding medium is not higher than +40℃ and not lower than -5℃; and the 24-hour average does not exceed 35℃ (except for special orders).

◆The relative humidity at the installation site is not more than 50% at the maximum temperature of +40℃; there can be high relative humidity at lower temperatures, such as 90% at 20℃, and special measures should be taken for the occasional condensation due to temperature changes.

◆The relative humidity of air of humid and hot belt type circuit breaker does not exceed 95% at +25℃.

◆The pollution level is Ⅲ.

◆The installation category of the main circuit of the circuit breaker is Ⅲ, and the installation category of the auxiliary circuit and control circuit not connected to the main circuit is Ⅱ.

◆The circuit breaker is suitable for use in electromagnetic environment A.

◆The circuit breakers in the humid heat zone can withstand the effects of humidity, heat, salt spray and mold.

◆The circuit breaker should be installed in a place where there is no danger of explosion and no conductive dust, no corrosion of metals and no damage to insulation.

◆In a place where there is no rain or snow attack.

◆The circuit breaker should be installed according to the user's manual of the product.


Model number and meaning

◆The models and their meanings are as follows.

1.jpg


◆Detachment mode and internal accessory code

22.jpg


Main features

◆Residual current three-phase protection: IDM1L, IDM8L plastic case leakage type circuit breakers to achieve ground fault protection, conventional leakage protection module with residual current protection circuit breakers work power sampling for two phases, this series of circuit breakers for three phases, if the lack of either phase, the circuit breaker leakage protection module can still work normally;.

◆Site adjustable: rated residual action current I△n and residual current action time (non-delayed and delayed) can be adjusted on site according to the actual situation.

Low voltage protection: when the phase voltage is reduced to 85V, the leakage protection module can still work normally; ◆Low voltage protection: when the phase voltage is reduced to 85V, the leakage protection module can still work normally.

◆Leakage alarm output function: When the residual current of the equipment or line reaches or exceeds the set value, the circuit breaker with the leakage alarm unit module outputs a signal with no source contact to drive the corresponding alarm device.

◆Installation interchangeability: The size is the same as M1 series circuit breakers (except M1-630), so the installation has good interchangeability.


主要技术参数

23.jpg

Note: 1. This series of three-pole circuit breakers connected to a three-phase load, the load can not take the neutral line, including the load control circuit power supply from the load end of the circuit breaker can not take the neutral line, otherwise the circuit breaker will create a false action;. 

2. When this series of three-pole and four-pole circuit breakers are used as single-phase loads, the incoming and outgoing phase lines are connected to the A pole and the neutral line is connected to the C pole, not to the B pole.


High altitude capacity reduction factor

24.jpg


For power distribution protection

图层72.jpg


Protective Features

◆For power distribution protection

图层73.jpg

◆电动机保护用

图层74.jpg


Circuit breaker distribution protection characteristic curve

25.jpg


Circuit breaker motor protection characteristic curve

26.jpg


Shape and mounting dimensions

◆Outline and mounting dimensions of front panel wiring

2.jpg


◆Outline and mounting dimensions of the rear wiring of the board

28.jpg


◆The outline and installation dimensions of behind-board insert type wiring

29.jpg

Note: Behind the board wiring, behind the board plug-in shape and installation, opening dimensions, subject to the attached physical size, the relevant dimensions of this information annex for reference only!!


Internal and external accessories

◆Internal Accessories

According to the needs of the user circuit breaker accessories can be directly lead out (wire length of 50cm, special requirements when ordering instructions), or add terminal.

图层80.jpg

Note: When the rated control power supply voltage is DC24V, there are two solutions. Scheme 1: DC24V shunt-excitation decoupler is used, but the following conditions should be satisfied. The maximum length of copper wire (each of the two wires) shall meet the conditions in the following table, and the power supply at the terminal of the derailer shall meet the minimum 50W requirement.

Note: The power of the undervoltage decoupler is shown in the following table

30.jpg


图层82.jpg

图层83.jpg

图层84.jpg

◆External Accessories

31.jpg

Order need to know: when ordering, please write down the type specification of the earth leakage circuit breaker and the order quantity, with ⽋ voltage decoupler, sub-excitation decoupler or electric operating mechanism, please specify the voltage value of working voltage or control power supply voltage, if the air temperature exceeds +40℃ or the lower limit is lower than -5℃, please specially declare.

If you order IDM1L/8L-250/4300 plastic case earth leakage circuit breaker, rated current 180A, leakage current: 100mA, 300mA, 500mA, time delay type 0.4s, 20 units.

Note: The specific size of the operating mechanism is subject to the actual size, the size of this information is for reference only!