The dry-type transformer
 produced by the transformer manufacturer is an important power 
equipment. Generally speaking, the application of the transformer is 
also relatively extensive. In all the faults of the transformer, 
attention should be paid to the type and solution of the fault of the 
transformer, so that for the future The application of the transformer 
and the resolution of the fault will have greater benefits. What are the
 types of transformer faults and the types of faults? Let's take a look 
with the editor of our transformer manufacturer: we all know that 
dry-type transformers play an important role in adjusting and improving 
the voltage in the circuit , For dry-type transformers, its adjustment 
must be adjusted according to the specific dry-type transformers in the 
circuit. Generally, dry-type transformers have five gears, and each gear
 has a different adjustment method. But usually it is adjusted according
 to the voltage level.
1. Dry-type 
transformer winding and inter-turn insulation fault. The insulation 
between windings and turns is the part that is more prone to failure. 
Long-term overload operation or poor heat dissipation conditions and 
long service life are easy to make the insulation of the transformer 
windings age and brittle, and the electrical strength is greatly 
reduced. Voltage fluctuations may also break down the insulation. Water 
in the transformer oil will greatly reduce the insulation strength and 
cannot withstand the allowable voltage, resulting in insulation 
breakdown. In the high and low voltage winding parts, due to the 
expansion of the insulation, the oil passage is blocked, which will also
 affect the heat dissipation, and the insulation will be too old, 
resulting in a short-circuit fault. Due to imperfect lightning 
protection measures, insulation breakdown may also occur.
2.
 Lead wire insulation failure. The transformer lead is connected to the 
external circuit through the inner cavity of the transformer bushing, 
and the lead is insulated by the bushing. If the casing is not tightly 
closed and water enters, it will cause the insulation to be damp and 
break down. In severe cases, the fuel tank will be exposed to the air, 
resulting in internal flashover and wiring failure.
3.
 Core insulation failure. The iron core of the transformer is made of 
stacked silicon steel sheets. There is an insulating paint film between 
the silicon steel sheets. If the silicon steel sheets are not fixed 
properly, the paint film will be damaged and eddy current will be 
generated. The core screws, weights and other components that clamp the 
iron core love you. If the insulation is damaged, overheating will also 
occur. In addition, iron filings and iron slag falling into the 
transformer will cause iron core failure.
4.
 Flashover and explosion of dry-type transformer bushing. The 
high-voltage side of the transformer mostly uses capacitor bushings, 
which have trachoma or cracks due to poor porcelain quality, defects in 
the capacitor itself, internal free discharge, and even if the bushing 
is not well sealed, there is oil leakage, and if the bushing is dirty, 
flashover and explosion may occur.
5. The tap changer is faulty. The fault of the tap changer is one of the common faults of the transformer. It is often caused by insufficient contact area, resulting in poor contact and short circuit fault, which eventually burns out the transformer.







 
 
 