Energy Data Center All In One Module
 
  
                    Details
Energy Data Center All In One Module
Feature:
*All-in-one cabinet
*High availability
*Efficient energy saving and environmental protection
*Save room area: All-in-one design, save more than 40% of the area of the traditional server room.
*Save construction time: High frequency type of UPS power supply, machine efficiency meet 93%.
*Simplify operations
*Flexible capacity
Fields of application
Business outlets (telecom, finance, energy, broadcasting, retail...
small enterprise
Large corporations, government, education, medical branches
Cloud Computing Edge Data Center
Specifications
10KVA~20KVA
| Model | H2P10KT3 | H2P10KT6 | H3P10KT6 | H3P20KT6 | B2P10KT7 | H3P10KT7 | B3P20KT12 | B4P20KT12 | ||
| Voltage | IT capacity | 8000W | 8000W | 8000W | 16KW | 8000W | 8000W | 16KW | 16KW | |
| UPS capacity | 10KVA | 10KVA | 10KVA | 20KVA | 10KVA | 10KVA | 20KVA | 20KVA | ||
| Voltage | 10KVA: 220V Input & output; 20kVA: 380V or 220V Input (adjustable)/ 220V output | |||||||||
| Lightning protection/distribution | Lightening protection at C level, overal control of mains input, UPS input, UPS output shunt, baypass maintanance, electricity meter indicator | |||||||||
| Cooling | Air conditioner Mode | 3KW Mode/pc (Outdoor not available) | 3KW Mode/ 2pcs (Outdoor not available) | Mode/pc, outside available | Mode/pc, outside available | |||||
| Cooling capacity | 3KW | 6KW | 7.5KW | 12.5KW | ||||||
| Emergency Ventilation | Yes | |||||||||
| Cabinet | recommended cabinet QTY | 1+1 | 1+1 | 1+2 | 1+2 | 1+1 | 1+2 | 1+2 | 1+3 | |
| Usuable Space | 38U+42U | 34U+42U | 38U+42U+42U | 24U+42U+42U | 26U+42U | 26U+42U+42U | 14U+42U+42U | 14U+42U +42U+42U | ||
| PDU QTY | 8 bit 16A/ 4pcs | 8 bit 16A/ 6pcs | 8 bit 16A/ 4pcs | 8 bit 16A/ 6pcs | 8 bit 16A/ 8pcs | |||||
| Enclosed heating and cooling aisle | Fully enclosed, emergency ventilation system at the top, front and rear cabinet | |||||||||
| Lighting | LED lighting at the top, front and rear cabinet (lights on when doors opened) | |||||||||
| Cable column | One cable column at the rear, left and right of the cabinet | |||||||||
| Monitoring | Items under Monitoring | UPS, air conditioner, temperature&humidity, smoke sensor, door magnetic, access control, water sensor, SMS alert | ||||||||
| Display | 15 inches integrated unit with LCD & touch screen | |||||||||
| Firefighting | fire extinguisher | 6/8/10 kg suspended heptafluoropropane automatic fire extinguisher ( other models optional) | ||||||||
| Battery | 10 mins Backup | 2U battery pack | 4U battery pack | 2U battery pack | 4U battery pack | |||||
| 30 mins Backup | 6U battery pack | battery pack | 2U battery pack | battery pack | ||||||
| Backup time extension | Install battery pack with large capacity. It can be put inside or outside the cabinet.The specific height is calculated according to the actual configuration. | |||||||||
| Dimension | W(mm) | 1470 | 2070 | 1200 | 1800 | 2400 | ||||
| L(mm) | 1200 | |||||||||
| H(mm) | 2000 | |||||||||
| Environment | Temperature | 0-45℃ | ||||||||
| Humidity | Relative humidity 0-95%, no water condensation | |||||||||
| Altitude | <1000m,full power may not be reached if over 1000m | |||||||||
| Customized service: According to customer needs to provide a wealth of options and customized services | ||||||||||
 